Module reference - Blackout for TrueSight
As for other modules, the main configuration files are in $PRODUCT_HOME/config but are overriden by the $PRODUCT_HOME/config/custom ones.
Review and update the following configuration parameters.
Parameter |
Description |
Default/typical value |
BlackoutProfilsModuleName |
Name of the associated Profile module |
BlackoutProfils |
CellName_EM |
Event management cell name for Blackout Management |
EM |
CellName_SIM |
Service Impact management cell name for Blackout Management |
SIM |
cellule_EM_ExtendTimeCapable |
Set if cell is Extend Time capable (Cell 7.4 or greater) |
1 if cell > 7.4 0 if cell < 7.4 |
ConfirmDestroy |
Option to confirm or not blackout removal |
1 : Ask for reason on blackout delete 0 : No question while deleting period |
CommentaireDefault |
Default comment |
No comment |
CommentMinSize |
Comment min size |
5: At least 5 characters need in order to have a valid comment |
CustomBOFileName |
Name of the file (as stored in the $PRODUCT_HOME/config/custom folder) storing custom blackout definitions |
custom_periods.cfg |
CustomPeriodsActivated |
Determines whether custom blackouts (see that section) are enabled or not. |
1 |
DefaultDuration |
Default duration for date based creation blackouts (seconds) |
600 |