Skip to main content

Module Reference - DDA Replication for TrueSight

Refer to the Data Editor reference section for common parameters.

Custom parameters include :

Parameter

Description

Default/typical value

[Custom] section

BackupFolder

Location of temporary and backup data files

./data/DDAReplication/Backups

BackupFolderCleanupDays

Number of days after which backup files (in BackupFolder) are deleted. Disregarded if value is negative.

-1

CustomActions

Custom context menu configuration, do not edit

TriggerReplication,History

TriggerReplication

Script running the replication task. Change the script extension from .cmd to .sh on linux systems

cmd:./Tools/bin/TriggerReplication.cmd"

History

Custom context menu configuration, do not edit

link:/modules/DDAModifier/ViewDeleteDDAModifier.php?ConditionsOrder=1&CondSlotName1=TaskUDID&Operator1=equals&ModuleName=DDAReplicationLog&CondValue1=MC_UDID&startCond1=&endCond1=

LogResultToFile

Flag indicating if replication task execution results should be logged to a file.

1

LogResultFile

Path to the replication task execution logfile.

i The size of the logfile is not monitored for size/growth.

../../log/DDAReplication.log

LogResultFileSize

Maximum size (in bytes) after which the logfile is rotated

5242880

LogResultFileNumber

Number of rotated logfiles kept

5

SendResultAsEvent

Flag indicating if replication task execution results should be sent as an event to the SendResultCell

1

SendResultAsData

Flag indicating if replication task execution results should be logged as entries in the DDAReplicationLog DDA table on SendResultCell

1

SendResultCell

Name of the cell that receives the events and log data.

(empty)