Required network ports
The following table summarizes communication ports that need to be open between the different ProactivePack components.
As all ports can be configured, only the default or typical values are presented.
Source |
Destination |
Port (default) |
Comments |
Module requiring |
User workstation |
Appliance |
80/443 |
http[s] protocol |
All |
User workstation |
Appliance |
1000 |
http[s] protocol for the webmin interface of the ProactivePack appliance |
All |
Appliance |
Target cell(s) |
1828 |
CLI (mquery etc) initiated from the Appliance. ProactivePack can target multiple cells on multiple systems |
QuickQueries, Data Editor, Data Replicator, Blackout, Calendar |
Appliance |
SMTP server |
25 |
Email generation by the ProactivePack server |
QuickQueries, Self-Service Monitoring Portal |
Appliance |
TrueSight Presentation Server |
80/443 |
http[s] protocol |
Self-Service Monitoring Portal (TSOM) and TSPS authentication |
Appliance |
TrueSight Presentation Server database |
5432 |
Postgres DB connection |
Self-Service Monitoring Portal (TSOM) |
Appliance |
BMC Helix Operations Management |
443 |
BHOM communications |
All BHOM-oriented modules. |