Overview
The blackout management module allows the definition of event and CI blackouts from a web interface. The module has a granular security model that can be configured to precisely determine the type and duration of blackouts that users/groups can set.
The module also provides extended customization capabilities.
How it works
The blackout module relies on specific classes and rules that must be loaded by the cell which will implement the blackout. See installation section for details.
The blackout module uses the cell command line (mquery, mposter, etc) to set and query the blackouts within the cell.
On standard Blackout as well as on Custom Blackouts, when using regular expressions the cell will perform a case non sensitive and multi lines regular expression check on events.
How events are managed
Depending on the action chosen in the blackout definition dialog, target events will be managed differently :
Action during blackout : Set event to blackout and reopen at end if not closed
ProactivePack selections
Effect on target events
Action during blackout
Action at blackout start
Set event to BLACKOUT and REOPEN at end
if not closed
Do nothing on already existing events

Include events since blackout creation

Include all existing events

Action during blackout : Set event to blackout
ProactivePack selections
Effect on target events
Action during blackout
Action at blackout start
Maintenance Period timelines
Set event to BLACKOUT
Do nothing on already existing events

Include events since blackout creation

Include all existing events
Action during blackout : Set event to closed
ProactivePack selections
Effect on target events
Action during blackout
Action at blackout start
Maintenance Period timelines
Set event to CLOSED
Do nothing on already existing events

Include events since blackout creation

Include all existing events